
TCL LIGHT COMMERCIAL ACROUND FLOW CASSETTE
Cassette 8-way Air Outlet
Wide Range Operation from -25℃ to 58℃
Snow blowing
Outdoor unit fan will blow in opposite during the winter to avoid snow accumulated on Fins
Full DC Design
Select DC inverter compressor and motor to ensure better energy saving and rellability of air conditioning system.
Soft Wind Panel (optional)
360°of outlet wind, 2565 micro-hole soft wind lades to break up the airflow, making the wind soft and comfortable to thebody.
1200mm Water Pump Lift
The Cassette has a built-in water pump, the maximum lift can reach 1200mm, which is conducive to the installation of drain pipes.
Multi Control
Air-zone Solutions
Compatible with the 3rd party zoning controller, realize independently adjustment for each room.
Double Wired Controller
The same air conditioner can be controlled by two wire control-lers by setting the primary and secondary wire controllers, you can adjust the most comfortable temperature for your child without going to the child’s room.
One Wired Controller
TCL also offers a solution that allows a single controller to operate multiple indoor units simultaneously, enabling central-ized management of your home’s entire air conditioning system. This improves energy efficiency, reduces power consumption, and delivers comfort and convenience through-out your space.
- Panel: MBQR-FC(360°)
- Power supply side: Outdoor
- IDU Power Supply (V~,Hz,Ph): 220-240V/50Hz/1P
- Capacity – Cooling (Btu/h): 24000(7500~25500)
- Capacity – Cooling (W): 7030(2200~7500)
- Capacity – Heating (Btu/h): 26900(7900~28500)
- Capacity – Heating (W): 7900(2320~8350)
- Capacity – Pdesignc (W): 7030
- Capacity – Pdesignh average (W): 6000
- Capacity – Declare capacity(-10℃) (W): 5450
- Capacity – Back up heating capacity(-10℃) (W): 550
- Electric Data(T1)- Rated Cooling Power Input (W): 2110(730~3300)
- Electric Data(T1)- Rated Heating Power Input (W): 2260(765~3100)
- Electric Data(T1)- Rated Cooling Current (A): 9.5(3.5~15.0)
- Electric Data(T1)- Rated Heating Current (A): 10.3(3.7~14.2)
- Annual energy consumption – Cooling (kwh/a): 402
- Annual energy consumption – Average (kwh/a): 2075
- Performance(T1)- EER (W/W): 3.33
- Performance(T1)- SEER (W/W): 6.2
- Performance(T1)- Energy Class: A++
- Performance(T1)- COP (W/W): 3.49
- Performance(T1)- SCOP (W/W): 4
- Performance(T1)- Energy Class: A+
- Indoor Fan Motor – Output Power (W): 60
- Indoor Fan Motor – Speed (Hi/Mi/Lo) (r/min): 590/500/430
- Indoor Unit – Indoor Air Flow(Hi/Mi/Lo) (m³/h): 1450
- Indoor Unit – Indoor sound power(S/H/M/L/Mute) (dB(A)): 59/56/52/49/47
- Indoor Unit – Indoor sound power(Standard rating conditions) (dB(A)): 56
- Indoor Unit – Indoor sound pressure(S/H/M/L/Mute) (dB(A)): 49/46/42/39/37
- Indoor Unit – Indoor sound pressure(Standard rating conditions) (dB(A)): 46
- Indoor Unit – Net Dimensions (W×D×H) (mm): 840×840×245
- Indoor Unit – Packing Dimensions (W×D×H) (mm): 920×920×270
- Indoor Unit – Net Weight (kg): 24
- Indoor Unit – Gross Weight (kg): 28
- Panel – Net Dimensions (W×D×H) (mm): 950×950×45
- Panel – Packing Dimensions (W×D×H) (mm): 1055×1055×90
- Panel – Net weight (kg): 6
- Panel – Gross weight (kg): 9
- Operation Temperature Range (℃): 16-31
- Control type: remote controller Optional Wired controller
Outdoor Unit
- Case: 845D(φ7×2)
- Type: heating pump
- Power Supply (V,Hz,Ph): Indoor:220-240V/50Hz/1P Outdoor:220-240V/50Hz/1P
- Max. Input Consumption (W): 3300
- Max. Current (A): 15
- Air Flow Volume (CFM): 2060
- Air Flow Volume (m³/h): 3500
- Noise Level (dB (A)): 54
- Noise Power Level (dB (A)): 64
- Net Dimensions (W×D×H) (mm): 845×342×700
- Packing Dimensions (W×D×H) (mm): 960×430×732
- Net Weight (kg): 40
- Gross Weight (kg): 44
- Refrigerant Type/Quantity – Type: R32
- Refrigerant Type/Quantity – Charged Volume (factory) (kg): 1.35
- Refrigerant Type/Quantity – additional Volume/Beyond 5 meters (g/m): 16
- Refrigerant Type/Quantity – CO2 equivalent (tonnes): 0.911
- Design Pressure (MPa): 4.5
- Refrigerant Piping – Liquid Side (mm): 1/4″
- Refrigerant Piping – Gas Side (mm): 1/2″
- Refrigerant Piping – Max. Length (m): 35
- Refrigerant Piping – Max. Height (mm): 20
- Ambient Temperature Range (Cooling/Heating) (℃): Cooling:-15-58/Heating:-25-24
- Wire – Power Wiring (Outdoor) (m㎡): 3×2.5mm²
- Wire – Connection Wiring (IDU&ODU) (m㎡): 5×2.5mm²
![TCL 2.5hp R410 UNITARY Series Cassette Unit Inverter AC [TCC-24CHRA/DV(02)]](https://varibuy.com/wp-content/uploads/2026/04/TCC-24CHRA-DV02.webp)
![TCL 2.5hp R410 UNITARY Series Cassette Unit Inverter AC [TCC-24CHRA/DV(02)] - Image 2](https://varibuy.com/wp-content/uploads/2026/04/TCL-TCC-24CHRA-DV02.webp)
![TCL 2.5hp R410 UNITARY Series Cassette Unit Inverter AC [TCC-24CHRA/DV(02)] - Image 3](https://varibuy.com/wp-content/uploads/2026/04/TCC-24CHRA-DV02-AC-1.webp)
![TCL 2.5hp R410 UNITARY Series Cassette Unit Inverter AC [TCC-24CHRA/DV(02)] - Image 4](https://varibuy.com/wp-content/uploads/2026/04/TCC-24CHRA-DV02-AC.webp)
![TCL 2.5hp R410 UNITARY Series Cassette Unit Inverter AC [TCC-24CHRA/DV(02)] - Image 5](https://varibuy.com/wp-content/uploads/2026/04/TCC-24CHRA-DV02-TCL-AC.webp)













![Midea 2hp R410 Air Conditioner [MSAF-18CRN1]](https://varibuy.com/wp-content/uploads/2023/04/MSAF-12CRN1-MIDEA-AIR-CONDITIONER-450x450.webp)
![LG 1.5hp ARTCOOL R410 Inverter AC | Ioniser, Smart Diagnosis, Dual Inverter Compressor [S4-Q12JARTB]](https://varibuy.com/wp-content/uploads/2023/05/S4-Q12JARTB-1-450x450.webp)
![Samsung 2HP R410 Split AC [AR18TRHGAWK/GA]](https://varibuy.com/wp-content/uploads/2023/04/AR12TRHGAWK-GA-450x450.webp)
![Midea 3.5HP R410 Floor Standing AC [MFTJ-36CRN1]](https://varibuy.com/wp-content/uploads/2023/03/MFPA-27CRN1-AC.webp)
There are no reviews yet.